Data Center Solutions
High-availability power and intelligent BMS/EMS for mission-critical facilities
Hyperscale, colocation and enterprise data centers require five-nines availability, fault-tolerant power distribution and granular thermal control. AEPL delivers turnkey Electrical, Instrumentation, BMS and EMS solutions engineered to Tier III and Tier IV standards.
From 33kV/11kV substations, 2N+1 redundant PCC/MCC switchboards and Active Harmonic Filters to unified Building & Energy Management Systems, we help operators achieve target PUE < 1.40 with zero unplanned downtime.

Unified electrical, cooling and safety infrastructure
Facility & HVAC automation
Closed-loop control of chillers, CRAHs/CRACs, cooling towers and VFD pumps with hot/cold aisle differential pressure and dew-point optimisation.
2N+1 power distribution
HT substations up to 33kV, VCBs, dry transformers, RMUs, compartmentalised PCC/MCCs (up to 6300A), APFC and Active Harmonic Filtering (< 3% THDi).
Fire safety & security
NFPA-compliant VESDA aspirating smoke detection, clean-agent suppression interlocks, under-floor leak detection, IP CCTV and biometric access control.
Core software deliverables for data center operators
Building Management (BMS)
Centralised monitoring of chillers, precision air handlers, dampers, DG sets, UPS banks and rack-level temperature/humidity sensors.
Energy Management (EMS)
ISO/IEC 30134-2 Level 3 real-time PUE tracking, Class 0.2S branch circuit metering, harmonic profiling and tenant billing analytics.
Fault Detection (FDD)
Automated Facility AnalytiX rules to detect valve hunting, economiser faults, filter choking and abnormal breaker thermal signatures early.
Programmable dashboards
Role-based NOC video-wall views, SLA compliance reports, capacity planning heatmaps and instant SMS/email incident escalation.

Engineered for zero-downtime switching and maintenance
Every switchgear lineup and control loop is architected so that any single bus, breaker, PLC CPU or communication link can be isolated and serviced without interrupting critical IT loads.
- Dual-bus 2N and 2N+1 electrical topologies with automated fast-transfer PLC logic ( grid ↔ DG ↔ UPS )
- In-house manufactured, ERDA type-tested panels up to 6300A / 65kA short-circuit rating
- Native multi-protocol integration across BACnet/IP, Modbus TCP/RTU, SNMP, OPC UA and IEC 61850
- Automated black-building / IST (Integrated Systems Testing) simulation prior to live load cutover